Precision: ≥0.5
Material: steel
Protection class: IP67
Limited overload: 300% F.S.
Maximum Load: 150% F.S.
Overload alarm: 100% F.S.
Load rating | t | 0.5/1/2/5 | |
klb | 0.25/0.5/0.75/1/1.5/2/2.5/2.5KLE/3/4/5/5KSE/7.5/10/15/20 | ||
Precision class | C3 | C5 | |
Maximum number of verification scale interval | nmax | 3000 | 5000 |
Minimum value of verification scale interval | Vmin | Emax/10000 | Emax/18000 |
Combined error | %F.S | ≤±0.020 | ≤±0.010 |
Creep(30 mins) | %F.S | ≤±0.016 | ≤±0.012 |
Influence of temperature on output sensitivity | %F.S/10℃ | ≤±0.011 | ≤±0.007 |
Influence of temperature on zero point | %F.S/10℃ | ≤±0.015 | ≤±0.014 |
0.0Output sensitivity | mV/N | 3.0±0.008 | |
Input inpedance | Ω | 350±3.5 | |
Output inpedance | Ω | 351±3.5 | |
Insulation resistance | MΩ | ≥5000(50VDC) | |
Zero point output | %F.S | ≤+1.0 | |
Compensation range of temperature | ℃ | -10~+40 | |
Safe overload | %F.S | 150 | |
Ultimate overload | %F.S | 300 |